B200 Dynamic Braking Module


The B200 Module is designed for use with drives operating at input voltages of 230/240/460/480 VAC.

Continuous Current Rating: 60 Amps
Peak Current Rating: 60 Amps
Input Voltage: 306/320/613/640 VDC
Turn On Voltage: 365/380/730/760 VDC

Minimum Resistance per Table Below
Drive Input Voltage 3Ø VAC Minimum Resistance Ohms ±5%
480 13.30
460 12.75
240 6.65
230 6.37

Continuous Brake Power per Table Below
Drive Input Voltage 3Ø VAC Brake Power HP Continuous
480 60.00
460 57.50
240 30.00
230 28.75

Maximum Number of Modules in Parallel: 25
Maximum Distance Between Control and Module: 10 Feet
Maximum Distance Between Module and Resistor Bank: 10,000 Feet
Ambient Temperature: 0°C to +50°C (32°F to 122°F)
Storage Temperature: -25°C to +85°C (-13°F to 185°F)
Altitude: 1000m (3280 ft) without derating
Humidity: 5% to 95% Non-condensing
Enclosure Type: Open style panel mount
Atmosphere: Non-corrosive, non-hazardous gas, vapor, or dust
Power Dissipation: 232 watts Continuous; 142 watts at 50% duty cycle; 112 watts at 33% duty cycle


Custom Power Technology, Inc.
N93 W14605 Whittaker Way
Menomonee Falls, WI 53051

Telephone: (262) 253-0880
Fax: (262) 253-0948
Email:Custom Power Technology